Products  |  Fluid Mechanics and Hydrology  |  Fundamentals of Aerodynamics and Airflow  |  HM 220
HM 220 Airflow Study Unit Show data sheet (pdf file)
Technical Description
The system comprises 2 components that are connected together for the experiments. A fan draws air through a section of pipe. The air flow rate can be measured with various measuring inserts such as a nozzle/orifice, Pitot tube or iris diaphragm. The measuring inserts are connected to a multiple tube manometer using hoses; the pressure differences can then be read on the manometer. Measuring glands are also fitted to the pipe section at evenly spaced intervals; these can be used for determining pipe friction, pressure losses or velocity profiles. The tube manometer can be tilted to increase precision and can be fixed in various positions. Open jet experiments can be performed at the fan outlet.
Learning Objectives / Experiments
· Measurement of air flow rate with a nozzle/orifice
· Measurement of air flow rate with a Pitot tube
· Measurement of air flow rate with an iris diaphragm
· Measurement of pressure loss in the straight section of pipe
· Measurements of pressure loss in pipe bends
· Determination of pipe friction
· Velocity profile in a pipe through which air is flowing
· Velocity profile in an open jet
· Preparation of system characteristic curves
Features
Study unit for investigations on air flow
Mobile system, flexible in use
Numerous measuring inserts
Comprehensive range of experiments
Available accessories
HM 220.01 -- Venturi Tube
HM 220.02 -- Boundary Layer Flow
Alternative products
HL 710 -- Ventilation Trainer
HM 225 -- Airflow Bench
HM 230 -- Compressible Flow Unit
HM 240 -- Principles of Airflow
Specification
[1] Study unit for comprehensive investigations on air flow
[2] System divided into 2 components that are set up at right angles to each other
[3] Component "1" with a radial fan and adjustable Pitot tube for open jet experiments on the fan outlet
[4] Component "2" with pipe section and diverse measuring inserts along with a 16-tube manometer for pressure measurements
[5] Pipe section with evenly spaced measuring glands
[6] Various fittings included
[7] 230V,~50Hz
Technical Data
Radial fan 530W
Max. volumetric flow rate 1320m³/h
Max. differential pressure 730Pa

Tube manometer, 16 tubes
Measuring range 600mmWG
Area distribution 10:5:2:1
Iris diaphragm, d adjustable from 20..70mm
Orifice/nozzle d=50mm
Aperture d=30mm
Dimensions and Weight
l x w x h: 2950 x 1300 x 1400 mm (both supports)
Weight : approx. 130 kg
Connections
230V,~50Hz
Scope of Delivery
1 study unit,
1 instruction manual
Order Details
070.22000 HM 220 Airflow Study Unit
© 2005 G.U.N.T. Gerätebau GmbH