Specification |
[1] Unit to determine the heat conductivity of building materials [2] Thermal conductivity and thermal resistance measurement in accordance with DIN 52612 [3] Reproducible clamping pressure due to clamping device [4] PC data acquisition, LabView software under Windows NT/2000/XP [5] 8 specimens: Armaflex, grey cardboard, PMMA, polystyrene, PS, POM, cork, plaster [6] Controller for heater and cooling plate [7] Heat transfer rate sensor, temperature sensor [8] Display for temperature and heat flux [9] 230V, 50 Hz, 1 phase |
Technical Data |
Electric heater mat: 500W, max. temperature: 200°C Specimens: 300x300mm, thickness up to max 75mm Sensor plate: 3W/m², -20...85°C Temperature sensors: 0...100°C and 0...200°C
System requirements: PC with Pentium III 600MHz, 1 PCI slot, 100MB free hard disc space, graphics card resolution 1024x768 pixel, true color |
Dimensions and Weight |
l x w x h : 750 x 580 x 806 mm Weight : approx. 35kg |
Connections |
230V, 50 Hz, 1 phase Cooling water supply |
Scope of Delivery |
1 complete unit, 1 set of specimens, 8 piece, 1 data acquisition card with software, 1 instruction manual |
Order Details |
060.37600 WL 376 Thermal Conductivity of Building Materials
|
|