Products  |  Thermodynamics, Heating and Sanitary Systems  |  Heating and Ventilation  |  HL 351
HL 351 Domestic Heating Furnace Show data sheet (pdf file)
Technical Description
Different operating points can be investigated by changing the oil pressure after the preset boiler water temperature has been reached. An integrated hot water circuit with plate heat exchanger simulates the heating circuit in a house. The heat generated can be dissipated via cooling water connections, enabling continuous operation. The heat transferred can be calculated. Connections for an external heating circuit are provided on the rear of the boiler. This allows the HL 351 to be expanded into a complete heating system using training panels from the HL series.
Learning Objectives / Experiments
- Function of an oil burner
- Operation of a boiler with an oil burner
- Burner adjustment during operation
- Temperature measurements in different areas of
  the combustion chamber
- Calculation of the thermal rating of a boiler
- Function of a plate heat exchanger
- Temperature distributions in a plate heat exchanger
Features
* Mobile demonstration unit for gas and oil burners
* Equipped with oil burner as standard
* Transparent oil tank
* Can be extended to form a complete heating system
Available accessories
HL 860 -- Exhaust Gas Analyser
Alternative products
HL 350 -- Oil Burner Demonstrator
HL 352 -- Domestic Water Heating System
HL 530 -- Training Panel Function of Gas Heater
Specification
[1] Functional boiler with oil burner
[2] l x w x h 1100x740x1760mm, 200kg
[3] Boiler with control unit
[4] Heating and cooling circuit equipped with
expansion vessel, pump, boiler safety group,
thermometers, water meter, heat exchanger
[5] Transparent oil tank with filling and bleed
connection, capacity 15ltr
[6] Dissipation of generated heat via plate heat exchanger and cold water connection
[7] 230V, 50Hz, 1 phase or 120V, 60Hz, 1 phase
Technical Data
Boiler: nominal rating: 17...21kW
Control unit with temperature limiter
Burner: nominal power: approx. 18kW
Circulating pump, 3 stages: 60W, max. flow rate: 60ltr/min, max. head: 4m
Plate heat exchanger: 3kW, 10 plates
Boiler safety group in accordance with DIN 4751, 2.5bar, 50kW
Measuring ranges:
- temperature: 1x 0...120°C / 2x 0...80°C
- water meter: 2.5m³/h
Dimensions and Weight
l x w x h : 1100 x 740 x 1700 mm
Weight : approx. 200 kg
Connections

230V, 50Hz, 1 phase or 120V, 60Hz, 1 phase

Cold water connection

Scope of Delivery
1 system, complete with oil burner,
1 instruction manual
Order Details
065.35100 HL 351 Domestic Heating Furnace
© 2005 G.U.N.T. Gerätebau GmbH