Technical Description |
 |
|
The unit contains sensors with digital displays to measure temperature, pres-sure and flow rate required for measurements and demonstrations on heating and sanitary systems. Various water circuits and a gas circuit can be selected. It is possible to adjust settings and investigate the performance effects while testing the function of external heaters (e.g. gas heaters, combination heaters, instantaneous heaters). An integrated plate heat exchanger allows the measur-ing system to operate without additional loads. Measured values can be trans-ferred to a PC. HL 820 can be attached to HL 090. |
 |
Learning Objectives / Experiments |
- Measurement of temperature, pressure, differential pressure and flow rate - Exercises on setting adjustment and investigating performance effects of heaters of the HL series |
 |
 |
Features
|
 |
|
* Additional measuring instruments with PC data acquisition for experiments with HL, ST and VS training panels |
 |
|
 |
Specification |
[1] Measuring system for HL, ST and VS units [2] Sensors: 4x temperature, 2x pressure, 1x differential pressure, 3x flow rate: 2x water, 1x gas [3] Plate heat exchanger, 3kW [4] Connections: cold and hot water, gas, heating feed and return with quick-action couplings [5] PC data acquisition with LabView software under Windows NT/2000/XP [6] 230V, 50Hz, 1 phase |
Technical Data |
Measuring ranges: temperature: 0...100°C; flow rates: water: 1...25ltr/min, gas: 10...90Nltr/min; pressure: 0...6bar; dp: 0...5000mbar System requirements: PC with Pentium III 600MHz, 256MB main storage, 250MB free hard disk space, PCI slot, free |
Dimensions and Weight |
l x w x h : 680 x 200 x 950 mm Weight : approx. 63 kg |
Connections |
230V, 50Hz, 1 phase can be connected to laboratory pipes for cold water, hot water, gas |
Scope of Delivery |
1 measuring system, 1 PC data acquisition card with software, 1 manual |
Order Details |
065.82000 HL 820 Universal Measuring System, Digital
|
|