ET 250 Photovoltaic Trainer Show data sheet (pdf file) Print page
Technical Description

The direct conversion of light energy into electrical energy is termed the photovoltaic effect. Since photovoltaic systems primarily use the visible spectrum of light they also work in diffuse light, such as when the sky is overcast. The system contains two solar cell arrays on a swivelling support mounted on castors. A load is simulated using a rheostat. Illuminance, surface temperature and the current and voltage generated are displayed digitally on a measuring unit. The unit is designed for use in daylight.

 

Learning Objectives / Experiments
- Relationship between incident radiation and
  electrical power
- Series and parallel operation of solar cells
Features
* Clearly laid out experimental set-up for the
  conversion of light energy into electrical energy1
* 2 solar modules on mobile, swivelling support
Specification

[1] Trainer on the photovoltaic production of energy
[2] Unit for use in daylight
[3] 2 solar cells on mobile and swivelling support, total power output 160W
[4] Series and parallel configuration possible
[5] lxwxh support: 1270x600x1450mm
[6] Measuring unit with digital displays for current, voltage, illuminance and temperature
[7] Rheostat as load
[8] Photodiode as illuminance sensor
[9] Supply voltage for measuring unit 86...264VAC, 47...63Hz, 1 phase

 

Technical Data

2x solar module

- nominal power output: 80W

- module surface area: 0.63m²

-max. current: 4.76A DC

- max. voltage: 16.9VDC

- voltage at no-load operation: 21.8VDC

- 36 cells, 125x125mm each

Measuring ranges of displays
- temperature: -40...150°C
- voltage: 0...200V
- current: 0...20A
- illuminance: 0...1000W/m²

- inclination: 0...360°

Rheostat 0...10 Ohm

 

Dimensions and Weight
lxbxh basic unit : 1270 x 600 x 1450 mm
lxwxh measuring unit: 360 x 310 x 160 mm
Weight : approx. 46 kg
Connections
86...264VAC, 47...63Hz, 1 phase
Scope of Delivery

1 solar module, complete with support

1 measuring unit

1 rheostat

1 set of cables

1 clinometer

1 instruction manual

Order Details
061.25000  ET 250  Photovoltaic Trainer