Specification |
[1] Model of a refrigeration system with closed water circuit that is used as a cooling load [2] l x w x h: 1000x600x1050mm, 100kg [3] Hot water circuit with tank, heater, pump and temperature controller [4] Hermetic piston compressor [5] Coaxial evaporator and condenser [6] Heater 300W [7] Sight glass in the refrigerant circuit [8] Instrumentation: bimetallic thermometers and rotameters [9] Refrigerant R134a [10] 230V, 50Hz, 1 phase |
Technical Data |
Compressor: power consumption: 150W at -10°C, refrigerating capacity: 280W at 0/32°C Coaxial tube heat exchanger: capacity: 2kW at 45°C condensing temperature, DT=7K Circulating pump, 3 stages: 30-45-60W, max. flow rate: 2.9m³/h, max. head: 4m Heater 300W Insulated water tank: 4.5ltr Measuring ranges: - temperature: 4x 0...60°C - flow rate: 2x 0...33ltr/h |
Dimensions and Weight |
l x w x h : 1000 x 600 x 1050 mm Weight : approx. 40 kg |
Connections |
230V, 50Hz, 1 phase Water supply |
Scope of Delivery |
1 complete unit, 1 instruction manual |
Order Details |
061.41900 ET 419 Heat Transfer in a Refrigeration System
|
|