Home           Products           Company           Contact us     
> Fundamentals of Thermodynamics
> Applied Thermodynamics
> Power Engines and Machines
> Internal Combustion Engines
> Refrigeration and Air Conditioning
> Heating and Ventilation
> Sanitary Systems
Products  |  Thermodynamics, Heating and Sanitary Systems  |  Power Engines and Machines  |  ET 860
ET 860 Steam Boiler Safety & Control Show data sheet (pdf file) Print page
Technical Description

The unit has been developed and built in accordance with the German technical regulations for steam and boilers (TRD 602).

 

The normal operation of a boiler as well as malfunctions in the water level and pressure sections of the boiler that trip the safety control system monitors the operation of the boiler and uses original parts with TRD approval.

 

In addition to the safety devices it is possible to switch in up to 15 system faults. Various fault conditions in system components can be simulated and their identification practiced.

 

The system comes equipped with PC data acquisition.

 
A supply of compressed air is required.

 

Learning Objectives / Experiments

- Model of an oil-fired steam boiler with operating and

  safety components
- PC data acquisition of characteristics of the

  monitoring elements
- Fault simulation:
  + burner with flame monitoring
  + pressure switch and limiter
  + feed water and level controller
  + high and low water limiter

Features

* Complete boiler simulation with fault circuits and PC
  data acquisition1
* Transparent boiler, clear view of measuring and

  control devices

Alternative products
HL 392C -- Safety & Control in Heating Systems
Specification

[1] Steam boiler simulation with oil burner
[2] Simulation: standard boiler operation; 15 faults that trigger the safety control system
[3] Safety control system according to TRD; safety elements: level switches, pressure switch and pressure limiter
[4] Transparent boiler
[5] Oil burner operated with compressed air
[6] Front panel with system diagram, signal lights and laboratory sockets
[7] PC data acquisition with LabView software under Windows NT/2000/XP
[8] l x w x h 1670x750x1685mm, 120kg
[9] 230V, 50/60Hz, 1phase or 120V, 50/60Hz, 1phase

 

Technical Data

Burner: light oil mechanical atomiser: 15kW
Boiler capacity: 110ltr
Supply tank: 100ltr
Circulating pump, 3 stages:

- power consumption: 25...60W

- max. flow rate: 60ltr/min

- max. head: 4m

Pressure switch: 0.5...6bar
Pressure limiter: 0.5...6bar
Safety valve: 10bar

 

Dimensions and Weight
l x w x h : 1670 x 750 x 1685 mm
Weight : approx. 120 kg
Connections
230V, 50/60Hz, 1 ph. or 120V, 50/60Hz, 1 ph.
Compressed air: 5bar
Scope of Delivery

1 simulation system

1 PC data acquisition card with software

1 digital multimeter

1 set of laboratory cables

1 instruction manual

Order Details
061.86000  ET 860  Steam Boiler Safety & Control
Print
© 2005 G.U.N.T. Gerätebau GmbH