HL 108 Domestic Heating Circuit Training Panel Show data sheet (pdf file) Print page
Technical Description
A pump circulates water through four radiators. The temperature of the radiators is set using thermostatic valves. A digital controller keeps the room temperature constant by driving the fourway mixing valve. This valve sets the temperature of the boiler return and the heating feed flow. Cold water connections enable the heat generated to be dissipated. The differential pressure across the pipe system is limited using a relief valve. Temperatures can be read on dial thermometers.
Supplies of hot and cold water are required for operation.
The training panel can be fitted to the HL 100 Universal Stand.
Learning Objectives / Experiments
· Familiarisation with a central heating system and its components
· Hydraulic compensation of radiators
· Function and operating behaviour of a circulating pump
· Function and operating behaviour of a heating controller
· Function and operating behaviour of a four-way mixing valve
Features
Training panel on heating systems and plumbing
Function of a central heating system
High level of relevance to practice due to use of commonly available commercial components
Accessory for the supply of hot water available
Available accessories
HL 090 -- Supply Bench for Training Panels
HL 100 -- Universal Stand for Training Panels
HL 108.01 -- Electrical Water Heater
HL 108.02 -- Gas Water Heater
HL 108.03 -- Water to Water Heat Exchanger Unit
Alternative products
HL 112 -- Radiator Training Panel
HL 300 -- Central Heating System
HL 305 -- Hydraulic Compensation of Radiators
Specification
[1] Training panel for heating engineering
[2] l x w x h 1750x400x1150mm, 90kg
[3] Room temperature controller with feedback of the feed temperature
[4] 4-way mixer DN20
[5] Circulating pump
[6] 7 rotameters
[7] 4 plate heat exchangers, 3kW each
[8] 5 bimetallic dial thermometers
[9] 2 cold water connections DN15
[10] 2 water connections for boiler DN15
[11] 1x differential pressure overflow valve
[12] 230V, 50Hz, 1 phase
[13] Hot water supply
Technical Data
Circulating pump, 3 stages: 60W, max. flow rate: 60ltr/min, max. head: 4m
Plate heat exchanger: capacity: 3kW, 8 plates
Heating controller with feedback of the feed temperature, inputs: 2 temperature sensors
Measuring ranges:
- temperature: 0...100°C
- flow rate: 2x 150...1600ltr/h, 1x 0...1000ltr/h, 4x 0...400ltr/h
Dimensions and Weight
l x w x h : 1750 x 400 x 1100 mm
Weight : approx. 90 kg
Connections
230V, 50Hz, 1 phase
Hot water supply, 1.5bar
Scope of Delivery
1 training panel, completely assembled,
1 instruction manual