Home           Products           Company           Contact us     
> Fundamentals of Thermodynamics
> Applied Thermodynamics
> Power Engines and Machines
> Internal Combustion Engines
> Refrigeration and Air Conditioning
> Heating and Ventilation
> Sanitary Systems
Products  |  Thermodynamics, Heating and Sanitary Systems  |  Refrigeration and Air Conditioning  |  ET 482
ET 482 Gas Heated Absorption Refrigeration Unit Show data sheet (pdf file) Print page
Technical Description
Unlike mechanically driven compression refrigeration systems, absorption systems use thermal energy directly. There are three circuits in the system: a water circuit, an ammonia circuit and a hydrogen circuit. The system comprises a generator, a condenser, an evaporator with a downstream gas heat exchanger, an absorber and a liquid heat exchanger. The generator is heated with gas not electricity. The unit can therefore be operated independent of the mains electricity.
A supply of propane gas is necessary for operation.
Learning Objectives / Experiments
· Principle of operation of an absorption refrigeration
  system with gas heater
· Familiarisation with the individual components in
  such a unit
· Demonstration of the refrigeration process
· Temperature measurement at relevant points in the
  system
Features
Simple demonstration model of an absorption refrigeration unit
Gas heater as heat source
Alternative products
ET 101 -- Basic Heat Pump Demonstrator
ET 415 -- Basic Refrigeration System
ET 480 -- Electrically Heated Absorption Refrigeration Unit
Specification
[1] Demonstration model of an absorption refrigeration unit
[2] Ammonia/water mixture as working medium, hydrogen as auxiliary gas
[3] Gas heater as heat source
[5] Temperature measurements using bimetallic dial thermometers
[6] Control panel with piezoelectric igniter and gas regulating valve
[7] Insulated vapour bubble pump / heater
[8] Operation with propane
[9] l x w x h: 750x400x600mm, 40kg
Technical Data
Absorption unit 527x180x482mm
Charge: ammonia / water mixture
Auxiliary gas: hydrogen
Heat source: propane
Fuel consumption: 18g/h

Piezoelectric igniter

Thermometers
1x -20...40°C
2x 60...60°C
1x 0..200°C
Dimensions and Weight
l x w x h: 750 x 400 x 600 mm
Weight : approx. 40 kg
Connections
Propane 30...50mbar
Scope of Delivery
1 refrigeration system, complete,
1 instruction manual
Order Details
061.48200 ET 482 Gas Heated Absorption Refrigeration Unit
Print
© 2005 G.U.N.T. Gerätebau GmbH