Specification |
[1] Mobile unit to determine low and high water contents in 2 phase liquid-water mixture
[2] Separating calorimeter for vapour content x<0.5 with water-cooled recooler
[3] Throttle calorimeter for vapour content x>0.95 with water-cooled condenser
[4] System diagram with functional schemes
[5] Steam line connections, ½"
[6] 230V, 50Hz, 1 phase; cold water supply |
Technical Data |
Steam: max. 240°C, max. 10bar
Safety valve: 10bar
Measuring ranges: temperature: 0...400°C, pressure (intake): 0...16bar, pressure (after expansion): -150...100mbar |
Dimensions and Weight |
l x w x h : 890 x 600 x 1890 mm
Weight : approx. 60 kg |
Scope of Delivery |
1 throttling calorimeter 1 graduated beaker, 250ml, 1 graduated beaker, 1000ml, 1 manual |
Order Details |
061.85050 ET 850.50 Throttling Calorimeter
|
|