Specification |
[1] Experimental set-up for flow-related experiments
[2] Closed water circuit
[3] Water supplied from tank via pump
[4] Flow rate measured with variable-area flowmeters
[5] Hose connections with rapid action hose couplings
[6] Pressure measurement with annular chambers
[7] Experiment instructions include illustration of fundamental principles |
Technical Data |
Measuring section for installation of various measurement objects, PVC, 32 x 1.8
Three pipe sections, straight, 1000mm:
1)½", St, galvanised 2)18 x 1, Cu 3)20 x 1.5,PVC
Pipe section, narrowing continuously: 20x1.5-16x1.2,PVC, widening continuously: 20x1.5-32x1.8,PVC
Pipe section with 90° angle/bend,20x1.5,PVC
Electronic pressure sensor: +/-2000mbar
Flowmeter, Precision Class 1.6
Measuring range: -small: 1060Ltr/h -large: 2800Ltr/h |
Dimensions and Weight |
l x w x h: 2000 x 780 x 1900 mm
Weight: approx. 145 kg |
Connections |
230V,~50Hz |
Scope of Delivery |
1 test stand, completely assembled, 1 set of measuring objects, 1 set of hose connections with couplings,1 instruction manual |
Order Details |
070.11000 HM 110 Hydrodynamics Trainer
|
|