Home           Products           Company           Contact us     
> Fundamentals of Thermodynamics
> Applied Thermodynamics
> Power Engines and Machines
> Internal Combustion Engines
> Refrigeration and Air Conditioning
> Heating and Ventilation
> Sanitary Systems
Products  |  Thermodynamics, Heating and Sanitary Systems  |  Applied Thermodynamics  |  WL 110
WL 110 Heat Exchanger Service Unit Show data sheet (pdf file) Print page
Technical Description
Using this benchtop unit the complex area of convective heat transfer can be investigated experimentally. Different heat exchanger modules (accessories) can be easily connected to the service unit, which includes a hot water tank with electrical heater and pump. The hot water temperature and the cold and hot water flow rates can be adjusted. The relevant temperatures and flow rates are measured using sensors and indicated on digital displays. It is possible to process the measured values on a PC using the data acquisition card and software (WL 110.05). A supply of cold water (mains or WL 110.20) is required.  
Learning Objectives / Experiments
- Function and operating performance of heat
  exchangers:
  + Tubular Heat Exchanger (WL 110.01)
  + Plate Heat Exchanger (WL 110.02)
  + Shell and Tube Heat Exchanger (WL 110.03)
  + Jacketed Vessel with Stirrer and Coil (WL 110.04)
- Temperature curves in parallel flow operation
- Temperature curves in counterflow operation
- Comparison of different types of heat exchangers
Features
* Service unit for various types of heat exchanger
* Optional processing of measured data on a PC
* Water connections using quick-action hose couplings
Available accessories
WL 110.01 -- Tubular Heat Exchanger
WL 110.02 -- Plate Heat Exchanger
WL 110.03 -- Shell & Tube Heat Exchanger
WL 110.04 -- Jacketed Vessel with Stirrer & Coil
WL 110.05 -- Data Acquisition System
WL 110.20 -- Water Chiller
Alternative products
WL 302 -- Concentric Tube Heat Exchanger / PC
WL 308 -- Heat Transfer at Pipe Walls
WL 315C -- Heat Exchanger Trainer
Specification
[1] Service unit for 4 different heat exchangers
[2] Benchtop unit l x w x h 1000x600x300mm, 80kg
[3] Warm water tank 10ltr with heater, pump and level switch
[4] Water connections using quick-action hose couplings
[5] Optional processing of the measured data on a PC
[6] Digital displays for 6 temperature sensors and 2 flow rate sensors
[7] Electronic temperature controller 0...80°C
[8] Stirrer connection and stirrer control for WL 110.04
[9] Drip tray
[10] 230V, 50Hz, 1 phase or 230V, 60Hz, 3 phase
Technical Data
Pump, 120W: max. flow rate 420L/h, max. head: 25m

Heater: 3kW, with thermostat: 0...80°C

Temperature sensors: -40...150°C
Flow rate sensors: 0...600L/h
Flow rate adjustment via finely adjustable manual valves
Dimensions and Weight
l x w x h : 1000 x 600 x 300 mm
Weight : approx. 80 kg
Connections
230V, 50Hz, 1 phase or 230V, 60Hz, 3 phase
Cold water connection: 500ltr/h
Scope of Delivery
1 service unit,
1 instruction manual
Order Details
060.11000  WL 110  Heat Exchanger Service Unit
Print