WL 302 Concentric Tube Heat Exchanger / PC Show data sheet (pdf file) Print page
Technical Description
The mobile test stand can be used to demonstrate the fundamentals of heat exchange between tubular flows. The unit is prepared for processing the measured data on a PC. WL 302 has a closed hot water circuit with pump, tank and tank heater. The water temperature is set on the heater with a thermostat. The cold water is taken from the network supply. Heat exchange takes place in a double-walled pipe. Manual valves permit both parallel and counterflow operation. The cold and hot water flow rates can be adjusted. The flow rate and relevant temperatures are recorded by electronic sensors. A display panel for the measured values is located on the instrument panel next to the copper pipework. The data acquisition card and software are included.  
Learning Objectives / Experiments
- Determination of temperature profile for parallel and
  counterflow operation
- Determination of mean heat flow for parallel and
  counterflow operation
- Determination of mean heat transfer coefficient
Features
* Clear experimental set-up on mobile test stand1
* Heat transfer in pipe flows1
* Processing of measured data on a PC1
* Closed, insulated hot water circuit1
* Complete experiment instructions
Alternative products
WL 110 -- Heat Exchanger Service Unit
WL 308 -- Heat Transfer at Pipe Walls
WL 315C -- Heat Exchanger Trainer
Specification

[1] Mobile test stand for experiments with a tubular heat exchanger
[2] l x w x h 1385x550x1850mm, 110kg
[3] Processing of measured data on a PC
[4] Closed hot water circuit, insulated with pump
and heater with thermostat
[5] Copper piping
[6] Manual valves in the cold water circuit enable to chose the operation mode parallel or counterflow
[7] Temperature measurement with 6 sensors
[8] Flow rate measurement with turbine flow meter, 0...200ltr/h
[9] System diagram
[10] Tank 28ltr
[11] 230V, 50Hz, 1 phase

 

Technical Data

Pump:

- power consumption: 140W

- max. flowrate: 3500ltr/h

- max. head: 4.3m
Heater: 2kW, with thermostat: 0...80°C
Temperature measurement: -40...150°C
Heat exchanger areas:

- hot side: 30159mm²

- cold side: 40212mm²

- mean transfer surface: 34945mm²
LabView software under Windows 2000 / XP

 

Dimensions and Weight
l x w x h : 1385 x 550 x 1850 mm
Weight : approx. 110 kg
Connections
230V, 50Hz, 1 phase
Cold water connection: min. 150ltr/h
Scope of Delivery

1 training stand, completely assembled

1 data acquisition card with software

1 manual

Order Details
060.30200  WL 302  Concentric Tube Heat
                     Exchanger / PC